READNOISE reference file

REFTYPE:

READNOISE

Data model:

ReadnoiseRefModel

The READNOISE reference file contains a pixel-by-pixel map of readnoise, which is used in estimating the expected noise in each pixel.

Reference Selection Keywords for READNOISE

CRDS selects appropriate READNOISE references based on the following keywords. READNOISE is not applicable for instruments not in the table. All keywords used for file selection are required.

Instrument

Keywords

WFI

instrument, detector, date, time

Standard ASDF metadata

The following table lists the attributes that are required to be present in all reference files. The first column shows the attribute in the ASDF reference file headers, which is the same as the name within the data model meta tree (second column). The second column gives the roman data model name for each attribute, which is useful when using data models in creating and populating a new reference file.

Attribute

Fully Qualified Path

author

model.meta.author

model_type

model.meta.model_type

date

model.meta.date

description

model.meta.description

instrument

model.meta.instrument.name

reftype

model.meta.reftype

telescope

model.meta.telescope

useafter

model.meta.useafter

NOTE: More information on standard required attributes can be found here: Standard ASDF metadata

Type Specific Keyword Attributes for READNOISE

In addition to the standard reference file keyword attributes listed above, the following keyword attributess are required in READNOISE reference files, because they are used as CRDS selectors (see Reference Selection Keywords for READNOISE):

Keyword Attr.

Fully qualified path

Instruments

detector

model.meta.wfi_mode.detector

WFI

Reference File Format

READNOISE reference files are asdf files with a single data array.

Data

Array Type

Dimensions

Data type

data

NDArray

4096 x 4096

float32

The ASDF file contains a single data array.